← Asset Watch · Generator profile
Aligned 5-minute series in NEM time (AEST). Coverage 93% of expected intervals.
No recent material events.
Same technology (Gas peakers) and region (SA). One row per site — DUIDs at the same site are combined and energy-weighted. Period 4 Nov 03:23 – 5 Nov 03:23 NEM time. Coverage 93%. Interval energy (max(0, SCADA MW) × 5/60 h) times the regional reference price, divided by that energy. A spot-market metric, not realised revenue.
| Asset | Energy MWh | Generation-weighted spot |
|---|---|---|
| Mintaro GT (this asset) | 1.9 | $16.83/MWh |
| Barker Inlet Power Station | 602.5 | $140.21/MWh |
| Bolivar Power Station | 0.0 | $16.83/MWh |
| Dry Creek GT (3 units) | 0.0 | — |
| Hallett GT | 54.2 | $-75.28/MWh |
| Ladbroke Grove (2 units) | 252.3 | $143.84/MWh |
| Quarantine (5 units) | 0.0 | — |
| Snapper Point Power Station | 0.0 | — |
Availability drop 20.0 MW or 15%; output drop 25.0 MW or 20%; high price from $300.00/MWh while output is below 25% of last-known availability; minimum 10 minutes; cooldown 60 minutes.
AEMO settlement timestamps are period-ending Australian Eastern Standard Time year-round. They do not observe daylight saving. A 14:05 stamp covers 14:00:01–14:05:00 AEST.
Energy and FCAS bid/rebid files (BIDDAYOFFER / BIDPEROFFER) are not ingested. AEMO publishes “Yesterday’s Bids” the next day; this release does not show bid bands, rebids or published reasons.
Binding constraint identities from dispatch are not ingested, so constraint overlays are not shown. State of charge is only stored from Next_Day_Dispatch INITIAL_ENERGY_STORAGE. It is next-day, not live, and is omitted when the field is absent.