Yatpool Solar Farm (YATSF1)

Solar · Yatpool Sun Farm Pty Ltd · Solar PV - Single axis tracking

Operational AEMO: In Service VIC1 Solar - Solar NEM data · 20h
94 MW
Registered nameplate capacity
20h revenue
$216
Capacity factor
0.9%
Revenue / MWh
$12.83
Est. SRMC
$0.25/MWh

Energy flow

Dispatch target (cleared) vs availability — 5‑minute intervals. VIC1 regional price (RRP) on right axis.

Key information
Capacity
94 MW

AEMO status In Service
Project status Operational (AI)

Flow Power project page states Yatpool Solar Farm has been generating clean energy since 2021; pv magazine Australia reported it connected to the grid in Apr 2021.

Region VIC1
Coordinates -35.91900, 142.96900 (AI)

BayWa r.e. case study describes the site as being in northwest Victoria; exact coordinates not stated in source, so coordinates are approximate site-area estimate from project location context.

MLF 0.8895
DUID YATSF1
Owner Yatpool Sun Farm Pty Ltd
Commissioned
Expected closure 2050
Closure date
Technology Solar PV - Single axis tracking
Fuel Solar - Solar
Module OEM Longi
Module / inverter supplier BayWa r.e.
Inverter OEM Sungrow
Inverter model SG20RT
Equipment confidence medium
Stats window
13 Jun 2026 00:00 → 13 Jun 2026 20:25 AEST

Dispatch & revenue

13 Jun 2026 00:00 → 13 Jun 2026 20:25 AEST

Energy revenue (× MLF)
$216
FCAS revenue (× MLF)
$0
FCAS volume
MWh
Dispatched
16.8 MWh
Available
MWh
Curtailed
MWh
Curtailment
of available
MLF used
0.8895
end of period

Revenue (× MLF)

Estimated $ per interval — energy (RRP) and FCAS (regional FCAS prices), both × MLF.

Methodology & assumptions

  • Dispatch & availability — AEMO Next Day Dispatch UNIT_SOLUTION (5‑minute intervals). Intervention intervals excluded.
  • Regional pricedispatch_price RRP matched by settlement time and NEM region (from generator registry).
  • Energy revenue (× MLF) — cleared MW × (5/60 h) × RRP × MLF.
  • FCAS revenue & volume — cleared FCAS MW from DISPATCHLOAD (raise/lower 6s, 60s, 5min, reg) × (5/60 h) × regional FCAS price × MLF. Volume is total FCAS enablement MWh across services.
  • Curtailment — estimated economic curtailment when availability exceeds dispatch target: max(0, availability − cleared) × (5/60) MWh.
  • Not settlement — estimates only. AEMO settlement applies DLF, rebids, constraints, and other factors not modelled here.
MLF history (AEMO daily)
Effective fromMLF
2024-07-01 0.8506
2025-07-01 0.8895

Financial overview

2026 real AUD. Monetary values are CPI-adjusted to 2026 real Australian dollars. Greenfield capex uses AEMO benchmarks when plant-specific cost is unknown.
Type
Solar (tracking)
Capacity
94 MW
Revenue (× MLF) (stats)
See dispatch stats link above
Est. SRMC
$0.25/MWh
Capex total (greenfield) default
$122.20M

Shown in table
$122.20M (2026 real AUD)

Capex refurbishment
Capex / MW default
$1,300,000

Shown in table
$1.30M (2026 real AUD)

Fixed OPEX (annual)
Fixed OPEX / MW-yr default
$20,000

Shown in table
$20.0k (2026 real AUD)

Variable OPEX / MWh default
$0.25

Shown in table
$0.25 (2026 real AUD)

Fuel cost / GJ
Heat rate GJ/MWh

Confidence: unknown · Status: needs review · Capex basis: unknown