Lancaster Solar Farm (LANCSF1)

Solar · Lancaster Solar Farm Pty Ltd as trustee for the Lancaster Solar Farm Trust · Solar PV - Single axis tracking

Construction AEMO: Anticipated VIC1 Solar - Solar NEM data · 24 hours
106 MW
Researched capacity
24 hours revenue
$451
Capacity factor
3.3%
Revenue / MWh
$5.33
Est. SRMC
$0.25/MWh

Energy flow

Dispatch target (cleared) vs availability — 5‑minute intervals. VIC1 regional price (RRP) on right axis.

Key information
Capacity (AI)
106 MW

PV Magazine Australia 2025; Lancaster Solar Farm is described as a 106 MW project.

AEMO status Anticipated
Project status Construction (AI)

PV Magazine Australia 2025; construction of Lancaster Solar Farm is underway near Shepparton.

Region VIC1
Coordinates

European Energy Australia project page says the site is approximately 9 km east of Kyabram, but no precise coordinates were provided in the supplied results.

MLF 0.9210
DUID LANCSF1
Owner Lancaster Solar Farm Pty Ltd as trustee for the Lancaster Solar Farm Trust
Commissioned
Expected closure
Closure date
Technology Solar PV - Single axis tracking
Fuel Solar - Solar
Module OEM Ingeteam
Module / inverter supplier Ingecon Sun Power B Series
Inverter OEM Ingeteam
Inverter model Ingecon Sun Power B Series
Equipment confidence high
Stats window
21 Jul 2026 18:05 → 22 Jul 2026 18:05 AEST

Dispatch & revenue

21 Jul 2026 18:05 → 22 Jul 2026 18:05 AEST

Energy revenue (× MLF)
$451
FCAS revenue (× MLF)
$0
FCAS volume
MWh
Dispatched
84.7 MWh
Available
MWh
Curtailed
MWh
Curtailment
of available
MLF used
0.9210
end of period

Revenue (× MLF)

Estimated $ per interval — energy (RRP) and FCAS (regional FCAS prices), both × MLF.

Methodology & assumptions

  • Dispatch & availability — AEMO Next Day Dispatch UNIT_SOLUTION (5‑minute intervals). Intervention intervals excluded.
  • Regional pricedispatch_price RRP matched by settlement time and NEM region (from generator registry).
  • Energy revenue (× MLF) — cleared MW × (5/60 h) × RRP × MLF.
  • FCAS revenue & volume — cleared FCAS MW from DISPATCHLOAD (raise/lower 6s, 60s, 5min, reg) × (5/60 h) × regional FCAS price × MLF. Volume is total FCAS enablement MWh across services.
  • State of chargeINITIAL_ENERGY_STORAGE (MWh at interval start) from UNIT_SOLUTION, published for bidirectional/storage units. Next-day data — the SOC line lags real time by up to a day.
  • Curtailment — estimated economic curtailment when availability exceeds dispatch target: max(0, availability − cleared) × (5/60) MWh.
  • Not settlement — estimates only. AEMO settlement applies DLF, rebids, constraints, and other factors not modelled here.
MLF history (AEMO daily)
Effective fromMLF
2026-02-24 0.9441
2026-07-01 0.9210

Financial overview

2026 real AUD. Monetary values are CPI-adjusted to 2026 real Australian dollars. Greenfield capex uses AEMO benchmarks when plant-specific cost is unknown.
Type
Solar (tracking)
Capacity
106 MW
Revenue (× MLF) (stats)
See dispatch stats link above
Est. SRMC
$0.25/MWh
Capex total (greenfield) default
$137.80M

Shown in table
$137.80M (2026 real AUD)

Capex refurbishment
Capex / MW default
$1,300,000

Shown in table
$1.30M (2026 real AUD)

Fixed OPEX (annual)
Fixed OPEX / MW-yr default
$20,000

Shown in table
$20.0k (2026 real AUD)

Variable OPEX / MWh default
$0.25

Shown in table
$0.25 (2026 real AUD)

Fuel cost / GJ
Heat rate GJ/MWh