Barn Hill

Wind · Barn HIll Wind Farm Pty Ltd · Wind Turbine - Onshore

Development AEMO: Publicly Announced Wind - Wind NEM data · 24 hours
186 MW
Registered nameplate capacity
Est. SRMC
$0.00/MWh
Key information
Capacity
186 MW
AEMO status Publicly Announced
Project status Development (AI)

DUID
Owner Barn HIll Wind Farm Pty Ltd
Commissioned
Expected closure
Closure date
Technology Wind Turbine - Onshore
Fuel Wind - Wind
Turbine OEM
Turbine model
Stats window
03 Jun 2026 17:20 → 04 Jun 2026 17:20 AEST

Dispatch & revenue

03 Jun 2026 17:20 → 04 Jun 2026 17:20 AEST

No DUID specified. Open this page from the stats list or a generator profile.

Financial overview

2026 real AUD. Monetary values are CPI-adjusted to 2026 real Australian dollars. Greenfield capex uses AEMO benchmarks when plant-specific cost is unknown.
Type
Wind (onshore)
Capacity
186 MW
Revenue (× MLF) (stats)
See dispatch stats link above
Est. SRMC
$0.00/MWh
Capex total (greenfield)
$500.00M

Shown in table
$500.00M (2026 real AUD)

How this was derived
The only specific project capex found is an AIP threshold of at least AUD 500 million for the up-to-360 MW Barn Hill wind project and associated infrastructure.

Reference
Australian Industry Participation Plan Summary - Project Phase / Operations Phase: Barn Hill Wind Farm (high confidence)
Source recorded 04 Jun 2026

Capex refurbishment
Capex / MW
$1,388,889

Shown in table
$1.39M (2026 real AUD)

How this was derived
A minimum implied capex per MW can be calculated from the AIP capex threshold and current maximum wind capacity. Because the capex value is a threshold, this is a lower bound only.

Reference
Australian Industry Participation Plan Summary - Project Phase / Operations Phase: Barn Hill Wind Farm (medium confidence)
Source recorded 04 Jun 2026

Capex / MWh storage
Fixed OPEX (annual)
$10.08M

Shown in table
$10.08M (2026 real AUD)

How this was derived
Annual fixed O&M is derived by applying the AEMO/Aurecon benchmark to AGL’s current 360 MW project scope.

Reference
2024 Energy Technology Cost and Parameters Review (medium confidence)
Source recorded 04 Jun 2026

Fixed OPEX / MW-yr
$28,000

Shown in table
$28.0k (2026 real AUD)

How this was derived
No Barn Hill-specific O&M contract was found, so the AEMO/Aurecon generic onshore-wind fixed O&M benchmark is used.

Reference
2024 Energy Technology Cost and Parameters Review (medium confidence)
Source recorded 04 Jun 2026

Variable OPEX / MWh
$0.00

Shown in table
$0.00 (2026 real AUD)

Fuel cost / GJ

How this was derived
Wind generation has no purchased combustion fuel cost; no Barn Hill fuel contract applies.

Reference
2024 Energy Technology Cost and Parameters Review (high confidence)
Source recorded 04 Jun 2026

Heat rate GJ/MWh

How this was derived
The onshore wind technology is resource-driven rather than heat-engine based, so heat rate and thermal efficiency are not meaningful assumptions.

Reference
2024 Energy Technology Cost and Parameters Review (high confidence)
Source recorded 04 Jun 2026

Confidence: medium · Status: ai estimated · Capex basis: reported · AI checked 04 Jun 2026

Notes
Barn Hill has an older publicly announced NEM listing at 124-186 MW / 62 turbines and no DUID. Current AGL and Australian Industry Participation documents describe an enlarged project of up to 50 WTGs, up to 360 MW, a new 275 kV transmission connection and a later-stage 270 MW / 4-hour battery. The capex value is the official AIP threshold '$500 million or more' for the project phase, so the numeric capex_total_aud is a lower-bound nominal 2026 reported value, not a final EPC or financial-close cost. capex_per_mw_aud is calculated using the current maximum wind scope of 360 MW; if calculated against the older 186 MW NEM listing, the lower-bound value would be about AUD 2.69 million/MW. Fixed O&M and variable O&M are not project-specific reported Barn Hill values; they use AEMO/Aurecon 2024 onshore-wind defaults. fixed_opex_annual_aud is calculated as AUD 28,000/MW-year × 186 MW because the generator record supplied by the user lists 186 MW; if the current 360 MW development scope is used, the same default gives AUD 10.08 million/year. Variable O&M is recorded as 0 because the AEMO/Aurecon default states variable O&M is included in fixed O&M. Heat rate and thermal efficiency are not applicable to wind generation. No generator-specific major refurbishment was found; AGL states asset life about 35 years, while AEMO/Aurecon notes onshore wind technical/operational life of 30-35 years with site-specific life extension and increased later-life maintenance. AGL project timeline states development approval on 31 January 2025, FID for wind farm and associated infrastructure anticipated late 2025, construction early 2026 and operations late 2028; the AIP plan lists completion date 11 January 2028.

Latest AI note (4 Jun 2026)

Barn Hill is not yet an operating NEM generator and no DUID was found. The supplied 186 MW capacity appears to reflect an older proposal: AEMO’s 2017 South Australian Fuel and Technology Report listed Barn Hill Wind Farm as 124-186 MW, while AGL’s current project materials describe up to 360 MW wind capacity plus a later-stage 270 MW / 4-hour battery, and AGL’s 2025 annual report map lists Barn Hill Wind Farm at 300 MW. Capex is reported only as a threshold: the approved AIP Plan states capital expenditure of $500 million or more for the current up-to-360 MW wind-farm project and associated infrastructure. capex_per_mw_aud is therefore a minimum value calculated as $500m / 360 MW, not a final EPC price. Fixed and variable O&M are generic AEMO/Aurecon 2024 onshore-wind assumptions applied to the current 360 MW wind scope; fixed_opex_annual_aud = 360 MW * $28,000/MW-year. No Barn Hill-specific O&M contract, PPA, turbine supply contract, debt/project-finance announcement, heat-rate/efficiency value, or exact closure date was found. AGL’s current webpage says development approval was granted on 31 January 2025 and that FID for the wind farm and associated infrastructure is anticipated in the second half of 2026, with the battery investment decision expected later. Earlier July 2025 AGL material stated late-2025 FID, so the current webpage is treated as the latest status. End-of-life treatment per AGL is either decommissioning or refurbishment subject to approvals, with decommissioning and rehabilitation plan requirements.

View 1 earlier AI note
4 Jun 2026

Barn Hill appears to have changed scope over time. Older AGL/AEMO listings describe 124-186 MW and the user-provided capacity is 186 MW; current AGL and Department of Industry materials describe an enlarged project of up to 360 MW plus transmission connection and a later-stage 270 MW / 4-hour battery. The reported capex is only a threshold: 'Capital expenditure: $500 million or more' for the current Barn Hill Wind Farm AIP project, not an exact EPC cost. Fixed O&M and variable O&M are not project-specific public values; they are estimated from AEMO/Aurecon 2024 onshore wind assumptions and scaled to the user-provided 186 MW capacity. For wind, heat rate and thermal efficiency are not applicable; operational direct emissions intensity is treated as 0 tCO2-e/MWh because there is no combustion fuel. AGL's live project page states FID for the wind farm is anticipated in the second half of 2026, whereas the July 2025 factsheet said late 2025; the later webpage is treated as more current. No major refurbishment notes found; asset life/life-extension basis is 30-35 years operational life, with AGL stating about 35 years.

Sources