Bango 999 Wind Farm (BANGOWF2)

Wind · BWF Nominees Pty Ltd as trustee for the BWF Trust · Wind Turbine - Onshore

Operational AEMO: In Service NSW1 Wind - Wind NEM data · 24 hours
85 MW
Registered nameplate capacity
24 hours revenue
$39.7k
Capacity factor
35.3%
Revenue / MWh
$55.30
Est. SRMC
$0.00/MWh

Energy flow

Dispatch target (cleared) vs availability — 5‑minute intervals. NSW1 regional price (RRP) on right axis.

Key information
Capacity
85 MW
AEMO status In Service
Project status Operational (AI)

Region NSW1
MLF 0.9355
DUID BANGOWF2
Owner BWF Nominees Pty Ltd as trustee for the BWF Trust
Commissioned Sep 2022
Expected closure 2025-07-02
Closure date
Technology Wind Turbine - Onshore
Fuel Wind - Wind
Turbine OEM
Turbine model
Stats window
03 Jun 2026 18:10 → 04 Jun 2026 18:10 AEST

Dispatch & revenue

03 Jun 2026 18:10 → 04 Jun 2026 18:10 AEST

Revenue (× MLF)
$39.7k
Dispatched
718.7 MWh
Available
548.8 MWh
Curtailed
MWh
Curtailment
0.0%
of available
MLF used
0.9355
end of period

Revenue (× MLF)

Estimated $ per interval using regional RRP and MLF effective on each day.

Methodology & assumptions

  • Dispatch & availability — AEMO Next Day Dispatch UNIT_SOLUTION (5‑minute intervals). Intervention intervals excluded.
  • Regional pricedispatch_price RRP matched by settlement time and NEM region (from generator registry).
  • Revenue (× MLF) — cleared MW × (5/60 h) × RRP × MLF. Chart uses MLF effective on each interval’s date; summary total uses MLF as at the end of the selected period (same as the revenue list).
  • Curtailment — estimated economic curtailment when availability exceeds dispatch target: max(0, availability − cleared) × (5/60) MWh.
  • Not settlement — estimates only. AEMO settlement applies DLF, rebids, constraints, and other factors not modelled here.
MLF history (AEMO daily)
Effective fromMLF
2024-07-01 0.9182
2025-07-01 0.9355

Financial overview

2026 real AUD. Monetary values are CPI-adjusted to 2026 real Australian dollars. Greenfield capex uses AEMO benchmarks when plant-specific cost is unknown.
Type
Wind (onshore)
Capacity
85 MW
Revenue (× MLF) (stats)
See dispatch stats link above
Est. SRMC
$0.00/MWh
Capex total (greenfield)
$173.77M

Shown in table
$173.77M (2026 real AUD)

How this was derived
Reported capex is for the whole Bango Wind Farm. DUID-level capex is estimated by pro-rating the reported whole-project value to BANGOWF2's 84.8 MW capacity.

Reference
Partners Group adds third Australian wind farm to Grassroots Renewable Energy platform (medium confidence)
Source recorded 04 Jun 2026

Capex refurbishment
Capex / MW derived
$2,049,180

Shown in table
$2.05M (2026 real AUD)

How this was derived
Unit capex is calculated from the reported whole-project value and capacity; no DUID-specific capex was publicly found.

Reference
Partners Group adds third Australian wind farm to Grassroots Renewable Energy platform (medium confidence)
Source recorded 04 Jun 2026

Fixed OPEX (annual)
$2.12M

Shown in table
$2.12M (2026 real AUD)

How this was derived
Annual fixed opex is derived from the GenCost onshore wind default fixed O&M and the provided BANGOWF2 capacity.

Reference
GenCost 2023-24: Final report (medium confidence)
Source recorded 04 Jun 2026

Fixed OPEX / MW-yr
$25,000

Shown in table
$25.0k (2026 real AUD)

How this was derived
No generator-specific fixed O&M cost was found; CSIRO/AEMO GenCost onshore wind default fixed O&M is used.

Reference
GenCost 2023-24: Final report (medium confidence)
Source recorded 04 Jun 2026

Variable OPEX / MWh
$0.00

Shown in table
$0.00 (2026 real AUD)

How this was derived
No generator-specific variable O&M cost was found; CSIRO/AEMO GenCost onshore wind default variable O&M is used.

Reference
GenCost 2023-24: Final report (medium confidence)
Source recorded 04 Jun 2026

Fuel cost / GJ
$0.00

Shown in table
$0.00 (2026 real AUD)

How this was derived
Wind has no purchased fuel input; fuel cost is set to zero using GenCost assumptions.

Reference
GenCost 2023-24: Final report (medium confidence)
Source recorded 04 Jun 2026

Heat rate GJ/MWh

How this was derived
Heat rate is not meaningful for wind; the model leaves heat rate null rather than treating it as a thermal conversion rate.

Reference
GenCost 2023-24: Final report (medium confidence)
Source recorded 04 Jun 2026

Confidence: medium · Status: ai estimated · Capex basis: estimated · AI checked 04 Jun 2026

Notes
BANGOWF2-specific construction cost was not found. Reported project capex is AUD 500 million total project value for the whole 244 MW Bango Wind Farm in 2019. The capex_total_aud shown here is a pro-rata allocation to BANGOWF2 using 84.8 MW / 244 MW, preserving the original nominal 2019 reported project cost. Fixed and variable opex are technology-default assumptions from CSIRO/AEMO GenCost 2023-24, not site-reported values. Wind heat rate and thermal efficiency are not applicable. Owner page states turbine design life at least 30 years; the 2022 Environmental Management Strategy also says the wind farm operational phase is expected to have a duration of 25 years, with decommissioning or upgrades possible.

Latest AI note (4 Jun 2026)

Bango Wind Farm is a 244 MW, 46-turbine onshore wind project. Public capex sources report only whole-project value, not DUID-specific BANGOWF2 value. Therefore capex_total_aud is estimated by pro-rating reported AUD 500m whole-project value by BANGOWF2 capacity of 84.8 MW over reported 244 MW total capacity. Whole-site nominal capex is preserved in the sources array. Fixed O&M, variable O&M, fuel cost and efficiency are technology default assumptions from CSIRO GenCost 2023-24 because generator-specific O&M contracts or costs were not found. Asset-life sources conflict: project EMS says operational phase expected duration 25 years, while the current Squadron project page states turbine design life at least 30 years; financial profile uses 25 years consistent with EMS and GenCost LCOE assumptions. No public major refurbishment has been found as of this research; decommissioning/repowering is expected at end of useful life.