Australia Plains Solar Farm

Solar · Gree · Solar PV - Single axis tracking

Publicly Announced Solar - Solar NEM data · 24 hours
200 MW
Registered nameplate capacity
Est. SRMC
$0.00/MWh

Stats window 03 Jun 2026 16:10 → 04 Jun 2026 16:10 AEST

Key information
Capacity
200 MW
Status Publicly Announced
Lifecycle Pre-operating
DUID
Owner Gree
Commissioned
Expected closure
Closure date
Technology Solar PV - Single axis tracking
Fuel Solar - Solar
Module OEM
Module / inverter supplier
Inverter OEM
Inverter model

Dispatch & revenue

03 Jun 2026 16:10 → 04 Jun 2026 16:10 AEST

No DUID specified. Open this page from the stats list or a generator profile.

Financial overview

2026 real AUD. Monetary values are CPI-adjusted to 2026 real Australian dollars. Greenfield capex uses AEMO benchmarks when plant-specific cost is unknown.
Type
Utility scale solar pv single axis tracking
Capacity
200 MW
Revenue (× MLF) (stats)
See dispatch stats link above
Est. SRMC
$0.00/MWh
Capex total (greenfield)
$324.14M

How this was derived
No site-specific capex was found; GHD/AEMO provides a close technology-and-size match for estimating Australia Plains solar-only capex.

Reference
2025 Energy Technology Cost and Technical Parameter Review (medium confidence)

Capex refurbishment
Capex / MW
$1,620,710

How this was derived
Per-MW AC value is calculated from the GHD/AEMO 200 MW AC representative project total.

Reference
2025 Energy Technology Cost and Technical Parameter Review (medium confidence)

Capex / MWh storage
Fixed OPEX (annual)
$2.88M

How this was derived
Representative large-scale solar PV O&M assumption provides the annual fixed O&M estimate for a 240 MW DC / 200 MW AC plant.

Reference
2025 Energy Technology Cost and Technical Parameter Review (medium confidence)

Fixed OPEX / MW-yr
$14,400

How this was derived
Schema value is normalised to AUD/MW AC/year while preserving GHD's DC-basis assumption in the excerpt.

Reference
2025 Energy Technology Cost and Technical Parameter Review (medium confidence)

Variable OPEX / MWh
$0.00

How this was derived
Separate variable O&M is not modelled; it is included in fixed O&M.

Reference
2025 Energy Technology Cost and Technical Parameter Review (medium confidence)

Fuel cost / GJ
$0.00

How this was derived
Solar PV uses solar irradiance rather than a purchased fuel, so fuel cost is set to zero.

Reference
2025 Energy Technology Cost and Technical Parameter Review (high confidence)

Heat rate GJ/MWh

How this was derived
Heat rate is not meaningful for photovoltaic generation, so it is left null.

Reference
2025 Energy Technology Cost and Technical Parameter Review (high confidence)

Confidence: medium · Status: ai estimated · Capex basis: estimated · AI checked 04 Jun 2026

Notes
No project-specific capex, O&M contract, PPA or financing disclosure was found in public sources. Capex and O&M are therefore estimated from AEMO/GHD 2025 technology assumptions for a representative 200 MW AC / 240 MW DC single-axis tracking utility-scale solar PV project, excluding BESS. Estimated capex comprises EPC cost AUD 259.4m plus land/development AUD 64.742m = AUD 324.142m nominal 2025 basis. Fixed O&M is GHD/AEMO's AUD 12,000/MW DC/year, applied to 240 MW DC = AUD 2.88m/year, equivalent to AUD 14,400/MW AC/year for the 200 MW AC export capacity. Variable O&M is treated as AUD 0/MWh because GHD states it is included in fixed O&M. The official project scope includes 200 MWac solar plus 400 MWh BESS; the provided generator record shows storage blank, and the financial values here are for the solar generator only. GHD notes major refurbishment is likely to involve inverter refurbishment/replacement at about half-life and possible expenditure on tracking drive mechanisms; modules are generally assumed not to be replaced except for faults/failures. AEMO's 2025 SAER lists Australia Plains Solar Farm as a publicly announced 200 MW solar farm with storage capacity NA, while Green Gold Energy materials describe the broader APSP as 200 MWac solar plus 400 MWh BESS with DA on 6 February 2025 and an 18-month construction period.

Sources